Product Datasheet Search Results:

BVP:253915.pdf296 Pages, 14056 KB, Original

Product Details Search Results:

Siemens.com/BVP:253911
LXC0362-3W*-1AD* ANC.EQUIPM.UNIT,OPT.LENGTH, 1 O UTGOER Model Product designation trunking unit for LX busbar trunking system Product type designation LXC0362-3W*-1AD* General technical data Configuration of the busbars L1,L2,L3,N,N,PE Voltage Insulation voltage at AC / rated value 690\u00a0V at DC / rated value 800\u00a0V Protection class Protection class IP IP54, IP55 Electricity Number of circuits / in a trunking unit 1 Short-time current resistance (Icw) / at 1000 V / limited to 1 s / rated value 57\u00...
4587 Bytes - 15:20:50, 01 November 2024
Siemens.com/BVP:253914
LXC0362-LR L UNIT Model Product designation L unit (junction unit) for LX busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 50\u00a0Hz maximum 50\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 690\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / rated value / maximum 1\u00a0400\u00a0A Connections Conductor cross section / of the (PE)N 884\u00a0mm\u00b2 Mechanical Design Height 162\u00a0mm Width 350\u00a0mm M...
2386 Bytes - 15:20:50, 01 November 2024
Siemens.com/BVP:253918
LXC0362-LV L UNIT Model Product designation L unit (junction unit) for LX busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 50\u00a0Hz maximum 50\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 690\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / rated value / maximum 1\u00a0400\u00a0A Connections Conductor cross section / of the (PE)N 884\u00a0mm\u00b2 Mechanical Design Height 350\u00a0mm Width 162\u00a0mm M...
2386 Bytes - 15:20:50, 01 November 2024
Siemens.com/BVP:253919
LXC0362-LH L UNIT Model Product designation L unit (junction unit) for LX busbar trunking system Protection class Protection class IP IP54 Main circuit Operating frequency / rated value minimum 50\u00a0Hz maximum 50\u00a0Hz Operating voltage / at AC at 50 Hz / rated value / maximum 690\u00a0V Operating current for circuit 1 / at AC / at 50 Hz / rated value / maximum 1\u00a0400\u00a0A Connections Conductor cross section / of the (PE)N 884\u00a0mm\u00b2 Mechanical Design Height 350\u00a0mm Width 162\u00a0mm M...
2386 Bytes - 15:20:50, 01 November 2024

Documentation and Support

Use our online request for specific proposed solutions or send your technical question directly to a product specialist at request:

File NameFile Size (MB)DocumentMOQSupport
BVP:253339.pdf1.381Request
BVP:253340.pdf1.381Request
BVP:253338.pdf1.381Request
BVP:253345.pdf1.381Request
BVP:253346.pdf1.381Request
BVP:253344.pdf1.381Request
BVP:253341.pdf1.381Request
BVP:253343.pdf1.381Request
BVP:253342.pdf1.381Request